Condensate Management

Part of the air treatment process is managing the water and condensate, that develops during compression. We offer separation solutions, drain, detection and treatment of this condensate.

Want to know more?

Condensate Drains

The zero-loss drain is the industrial standard for reliable condensate management with the best quality and possibly the simples and most cost efficient way to avoid wasting large amounts of energy. 

Zero-loss Drains

Model

Drain capacity

Dimensions

Weight

Art. no.

  L/h L x W x H (mm) kg   
LD 100 1.6 136x60x120 0.42 2255330150
LD 101 Compact 4.03 160x69x120 0.5 2255330151
LD 101 3.3 163x69x140 0.6 2255330152
LD 101 L 5 163x69x140 0.6 2255330153
LD 200 8.07 163x69x155 0.7 4101000212
LD 200 L 10 163x69x155 0.7 2255330155
LD 202 16.14 163x69x214 1.2 4101000213
LD 202 L 20 163x69x214 1.2 2255330155
LD 203 85 188x130x230 2.8 4101000214
LD 204 200 247x130x230 3.45 2255330156

 

 

Other Drains

Model

Description

Dimensions

Weight

Art. no.

    L x W x H (mm) kg   
G120 Mechanical drain float, 250 l/h 156x108x111 0.9 79500000
E200 Automatic drain with timer - - 79520000
- Automatic timer drain - - 400470

 

 

Oil/Water Separators

Ecobox

Ecobox offers a compressor condensed cleaning solution with excellent performance for compressed air systems up to 30 l / s (60cfm). The Ecobox is designed specifically to provide an affordable condensed cleaning solution for piston compressors and small screw compressor installations. It is able to purify the compressor condensate into oil concentrates down to 15 ppm using a new, advanced filter medium.

Model

Flow

Max. Capacity

Connection

Dimensions

Weight

Art. no.

  m3/h l/min. in - out L x W x H kg  
Ecobox 1 < 100 1500 1/4" - 3/8" 140x140x240 1 8102046474
Ecobox 2 190 3180 1/2" - 1/2" 215x257x500 2.7 2255330002
Ecobox 3 570 9480 1/2" - 3/4" 345x282x654 3.6 2255330004
Ecobox 4 1400 23 340 1/2" - 3/4" 432x495x989 14.8 2255330006

 

 

OWS 25 - 5300

Depending on your needs, you can choose between two different types of cartridges: activated carbon and organic clay.

Activated carbon filters remove any oil left in the condensate after the first step.

Filtration with organic clay can be used in case of strong emulsions.

Model

Flow incl.  dryer

Flow excl. dryer

Dimensions

Weight

Art. no.

  m3/h m3/h L x W x H (mm) kg  
 Activated carbon filtration
OWS 25 43 54 250x147x216 1,2 8102046800
OWS 53 90 113 250x147x216 1,5 8102046804
OWS 106 180 225 390x278x428 5,8 8102046810
OWS 180 306 383 397x286x507 7,7 8102046811
OWS 360 612 765 490x396x576 13,1 8102046812
OWS 636 1808 1350 583x446x721 25,3 8102046813
OWS 1325 2250 2813 692x568x970 45,1 8102046814
OWS 2650 4499 5625 975x782x1000 86 8102046815
OWS 5300 8998 11 250 975x1600x1000 171,9 8102046816

Model

Flow incl. dryer

Flow excl. dryer

Dimensions

Weight

Art. no.

  m3/h m3/h L x W x H (mm) kg  
 Organoclay filtration 
OWS 25 CLAY  43 54 250x147x216 1,2 8102046800
OWS 53 CLAY 90 113 250x147x216 1,5 8102046804
OWS 106 CLAY 180 225 390x278x428 5,8 8102046810
OWS 180 CLAY 306 383 397x286x507 7,7 8102046811
OWS 360 CLAY 612 765 490x396x576 13,1 8102046812
OWS 636 CLAY 1808 1350 583x446x721 25,3 8102046813
OWS 1325 CLAY 2250 2813 692x568x970 45,1 8102046814
OWS 2650 CLAY 4499 5625 975x782x1000 86 8102046815
OWS 5300 CLAY 8998 11 250 975x1600x1000 171,9 8102046816

Aftercoolers

Compressed air will always be 100 % satuated with water when it leaves the compressor. But also the outlet temperature has a big influence on the water loads downstream for the compressor. To minimize the load and thus size - of the downstreams cooling and adsorptionsdryer - it its recommended to install an efficient aftercooler between the compressor and dryer. 

Air cooled Aftercoolers

Model

Flow

Max. pressure

Connection

Power supply

Dimensions

Weight

Art. no.

  m3/h bar   V/phase/Hz  L x W x H (mm) kg  
CA 1 66 15 G1" 230/1/50 400x320x957 19 2255330081
CA 2 126 15 G1" 230/1/50 400x320x957 20 2255330082
CA 3 222 15 G1 1/2" 400/3/50 490x368x1024 27 2255330083
CA 4 294 15 G1 1/2" 400/3/50 490x368x1024 29 2255330084
CA 5 390 15 G2" 400/3/50 764x355x1136 44 2255330085
CA 6 522 15 G2" 400/3/50 764x355x1136 48 2255330086
CA 7 774 15 G2" 400/3/50 775x466x1450 61 2255330087
CA 8 990 15 G2 1/2" 400/3/50 775x466x1450 66 2255330088
CA 9 1260 15 DN100 400/3/50 1616x564x1634 127 2255330089
CA 10 1560 15 DN100 400/3/50 1616x564x1634 143 2255330090
CA 11 1890 15 DN100 400/3/50 1560x790x1800 148 2255330091
CA 12 2520 15 DN100 400/3/50 1740x795x2000 166 2255330092
CA 13 3090 15 DN125 400/3/50 1850x830x2090 212 2255330093
CA 14 4500 15 DN125 400/3/50 2010x850x2300 315 2255330094

 

 

Water cooled Aftercoolers

Model

Flow

Max. pressure

Connection

Lenght

Diameter

Art. no.

  m3/h bar   mm mm  
CW 1 132 16 DN50 806 60.3 2255330095
CW 2 235 16 DN50 816 60.3 2255330096
CW 3 367 16 DN50 816 60.3 2255330097
CW 4 661 16 DN50 870 60.3 2255330098
CW 5 955 16 DN50 870 60.3 2255330099
CW 6 1323 16 DN80 1500 88.9 2255330100
CW 7 2205 16 DN80 1510 88.9 2255330101
CW 8 3087 16 DN125 1300 139.7 2255330102
CW 9 3969 16 DN125 1300 139.7 2255330103
CW 10 7056 16 DN200 1300 219 2255330104
CW 11 8967 16 DN200 1300 219 2255330105
CW 12 11 025 10 DN250 1300 273 2255330106
CW 13 16 170 10 DN300 1300 323.9 2255330107
CW 14 22 050 10 DN400 1300 406 2255330108
CW 15 26 460 10 DN400 1300 406 2255330109
CW 16 33 810 10 DN450 1300 457 2255330110
CW 17 45 570 10 DN500 1300 508 2255330111

 

 

Water Detectors

The WD gives an alarm as soon as a 3cl water level is detected. This alarm message is visible, audible and can be routed to a control room thanks to potential-free contact. The ball valve at the outlet is meant to release water after an alarm situation is closed during normal operation. 

Model

Max. pressure

Alarm level

Dimensions

Weight

Art. no.

  bar first/second  LxWxH (mm) kg  
WD 16 3 / 6.7 160x69x116 0x6 2255330112